Notifications
You must be signed in to change notification settings - Fork 18
Description
Atlasviewer works perfectly fine for me if I use a .nirs file + digpts file.
There is some support for reading .snirf files implemented in atlasviewer, but I'm not sure if it's really supposed to support reading of sourcePos3D, detectorPos3D, landmarkPos3D, and probe.landmarkLabels.
If point atlasviewer to a folder containing either of the .snirf files from this zip below, there is no automatic reading of the coordinates (atlasviewer does detect and read something from the file though). It's possible to force reading of the .snirf through Tools> Probe> Load in AV, but in that case the ficudials/lanmarkPos3D positions are not read in, only sourcePos3D and detectorPos3D. Note that I supplied two .snirf files, they have different landmarkLabels, and 2x12_atlasviewer_landmarknames.snirf has the same name (and order) of fiducials as digpts.txt.
Note that the combination of .snirf file and digpts.txt doesn't work either.
I'm not sure if this is expected/intended behaviour, or if there is something going wrong. As far as I can tell, the .snirf files conform to the snirf standards.