-
-
Notifications
You must be signed in to change notification settings - Fork 59
Description
Hoping someone can point me in the right direction.. I just finished the install of OpenNeptune on my neptune 4 max and was working on calibration. I ran the PID_TUNE_EXTRUDER and then had a thermal runaway shutdown. There was smoke and everything coming off the hotend.I can see that it was reading the temperature can anyone tell me why this happened or how to fix it?
Received 49.554006: b'{"id":281473310956064,"method":"gcode/script","params":{"script":"SET_HEATER_TEMPERATURE HEATER=extruder TARGET=170"}}'
MCU 'mcu' shutdown: ADC out of range
clocksync state: mcu_freq=84000000 last_clock=5152717141 clock_est=(39.893 3735123901 84002914.487) min_half_rtt=0.000300 min_rtt_time=31.001 time_avg=39.893(89.117) clock_avg=3735123901.679(7486114787.655) pred_variance=2201576070.334
Dumping serial stats: bytes_write=3065 bytes_read=11293 bytes_retransmit=9 bytes_invalid=0 send_seq=263 receive_seq=263 retransmit_seq=2 srtt=0.001 rttvar=0.000 rto=0.025 ready_bytes=0 upcoming_bytes=0
Dumping send queue 100 messages
Receive: 98 57.264012 56.768275 14: seq: 17, analog_in_state oid=23 next_clock=923952704 value=7585
Receive: 99 57.294162 56.768275 12: seq: 17, shutdown clock=901874357 static_string_id=ADC out of range
MCU 'mcu' shutdown: ADC out of range
gcode.CommandError: MCU 'mcu' shutdown: ADC out of range
Sensor 'extruder' temperature 463.532 not in range 0.000:330.000
[extruder]
heater_pin: PA7
sensor_pin: PA1
sensor_type: NTC 100K MGB18-104F39050L32
max_temp: 330