Made by PCsensor (http://www.pcsensor.com/index.php?_a=document&doc_id=6), metallic enclosure with blue TXT push button and titled "TEMPerHUM", windows driver TEMPer V24.4.4.zip.
It seems to be (I didn't opened enclosure) that used Silabs Si7006 sensor - http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7006-A10.pdf
Following request bytes - .data = (unsigned char[]){ 0, 1, 0x80, 0x33, 1, 0, 0, 0, 0 }

hid-query /dev/hidraw1 1 0x80 0x33 1
Device /dev/hidraw1 : 0c45:7402 interface 1 : RDing TEMPERHUM1V1.2
Writing data (9 bytes):
00 01 80 33 01 00 00 00 00
Response from device (8 bytes):
80 04 6b 80 43 32 2e 32
where - 80 04 and 2e 32 - technical (not interesting for me at least, please add info if matters)
6b 80 - temperature
43 32 - humidity

from sensor description -
_tempC = ((float)temp)_175.72 / 65536-46.8;
float relhum = ((float)rh)*125 / 65536 - 6;

lsusb -v output
Bus 002 Device 015: ID 0c45:7402 Microdia
Couldn't open device, some information will be missing
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 0 (Defined at Interface level)
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 8
idVendor 0x0c45 Microdia
idProduct 0x7402
bcdDevice 0.01
iManufacturer 1
iProduct 2
iSerial 0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 59
bNumInterfaces 2
bConfigurationValue 1
iConfiguration 0
bmAttributes 0xa0
(Bus Powered)
Remote Wakeup
MaxPower 100mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 1 Boot Interface Subclass
bInterfaceProtocol 1 Keyboard
iInterface 0
HID Device Descriptor:
bLength 9
bDescriptorType 33
bcdHID 1.10
bCountryCode 0 Not supported
bNumDescriptors 1
bDescriptorType 34 Report
wDescriptorLength 65
Report Descriptors:
** UNAVAILABLE **
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x81 EP 1 IN
bmAttributes 3
Transfer Type Interrupt
Synch Type None
Usage Type Data
wMaxPacketSize 0x0008 1x 8 bytes
bInterval 10
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 1
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 3 Human Interface Device
bInterfaceSubClass 1 Boot Interface Subclass
bInterfaceProtocol 2 Mouse
iInterface 0
HID Device Descriptor:
bLength 9
bDescriptorType 33
bcdHID 1.10
bCountryCode 0 Not supported
bNumDescriptors 1
bDescriptorType 34 Report
wDescriptorLength 41
Report Descriptors:
** UNAVAILABLE **
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x82 EP 2 IN
bmAttributes 3
Transfer Type Interrupt
Synch Type None
Usage Type Data
wMaxPacketSize 0x0008 1x 8 bytes
bInterval 10