Konnected Pro Ethernet Alarm Panel Configuration

This ESPHome configuration implements a local alarm system for the Konnected Pro Alarm Panel Pro (Ethernet) using Esphome. This config includes support for a Wiegand Hardwired Keypad to Arm/Disarm

Overview

This alarm panel provides a configurable state machine-based security system with keypad control, zone monitoring, and Home Assistant integration.

Features

Alarm States

  • Disarmed: System is inactive
  • Arming: System is arming with countdown
  • Armed Away: System is armed for away mode
  • Armed Home: System is armed for home mode
  • Pending: Motion detected while armed (triggers transition after timeout)
  • Triggered: Alarm is active

Keypad Controls

  • * key: Arms the system in Home mode
  • # key: Arms the system in Away mode
  • 4-digit PIN code: Disarms the system (code required)
  • Keypad includes LED indicator and beeper for user feedback

Zone Monitoring

Supports up to 8 monitored zones (zones 5-12) for doors, windows, and motion sensors. When armed, zone triggers transition to pending state and then trigger alarm state.

Configurable Settings

  • Arming Timeout: Delay before system fully arms (default: 10 seconds)
  • Pending Timeout: Delay after zone trigger before alarm activates (default: 60 seconds)
  • Trigger Timeout: Duration alarm remains active (default: 5 minutes)

Connectivity & Interface

  • Ethernet connectivity (LAN8720)
  • Built-in web server for local monitoring and control
  • Home Assistant API integration
  • Local PIN code validation

Outputs

  • Siren output (alarm1) can be triggered manually or automatically on alarm state
  • Keypad LED and beeper outputs

Hardware

  • Konnected Pro Alarm Panel ESP32
  • LAN8720 Ethernet interface
  • Wiegand keypad
  • Door/window/motion sensors on zones 5-12
  • Optional siren output

Configuration

Key settings are defined as substitutions at the top of the config file:

  • alarm_code: Master PIN code(s) for disarming
  • Zone names and GPIO assignments
  • Timeout durations
  • Device name and friendly name

Home Assistant Integration

The system exposes:

  • Alarm state sensor
  • Arm/Disarm services
  • Incorrect code counter
  • Individual zone binary sensors
  • LED and beeper controls