Releases: M10tech/Quatt-control
Releases · M10tech/Quatt-control
0.6.4 hysteresis2 adjust and send OT to boiler always
0.6.3 don't send OT messages until heater is initialised
- it takes 50s before heater function is first run - apply a small hysteresis to heater2 early heating activation point
0.6.2 remove clipping of room setpoint if upstairs is warmer than living
- this means upstairs can tune down the demand if it warms up in this situation - change hysteresis of heater1 from 0.2 to 0.1 degrees C
0.6.1 do not allow csp below 20
- it even managed to become -1 sending wrong value to opentherm CiC
0.6.0 make upstairs heater algorithm dumb so Quatt can be smart
- hypothesis is that CiC will reduce compressor level according to need - so when there is overshoot, but outside is cold, choose the level for maintain - this is an experiment, so success not guaranteed... - changed heater factor reset value to 105 = no restriction - changed CSP base default value to 30
0.5.3 make CH Set Point depend on outside temperature S3
- Homekit chsetpoint used as base, default 35 - if heater==1, CSP=base-S3/2 - if heater==2, CSP=base-S3*2
0.5.2 increase CHsetpoint of boiler with 2 degrees
- might prevent missing a switch-off detection of CiC
0.5.1 use CHsetpoint also for boiler
- else the boiler will overshoot and CiC will shut it down
0.5.0 make CHsetpoint to Quatt/CiC a characteristic
- for experimental reasons, manual control - was static 35 degrees Celcius, but boiler would stay off...
0.4.8 extend heater factor to negative values
- hysteresis for heater1 to 0.2 degrees - range from -1.00 to 1.00 - 1.05 means factor does not limit