48 changes: 35 additions & 13 deletions docs/source/everest_charging_stack.rst
Original file line number Diff line number Diff line change
Expand Up @@ -65,7 +65,7 @@ Also the BSP driver `CbTarragonDriver <https://github.com/chargebyte/everest-cha
(aka HAL) for this platform gained support for this.

A phase count switching setup always consists of two contactors which are controlled by the charging
stack more or less independently. There exists two different kinds of hardware setups which are
stack more or less independently. There exist three different kinds of hardware setups which are
different in the physical wiring:

* **serial** setup type: In this setup type both contactors are wired in 'series': while the
Expand All @@ -77,35 +77,56 @@ different in the physical wiring:
This ensures - in combination with the physical setup - a homogeneous view of the grid from the
car side. Thus the charger appears to be a single-phase only or a three-phase charger.

.. _switch-3ph1ph-serial:
.. figure:: _static/images/switch-3ph1ph-serial.drawio.svg
:width: 50%
.. _switch-3ph1ph-serial:
.. figure:: _static/images/switch-3ph1ph-serial.drawio.svg
:width: 50%

Example wiring with two contactors 'in series', both with auxiliary contacts for feedback generation.
Note, that both contactors must be rated for 400 V in this setup.
Example wiring with two contactors 'in series', both with auxiliary contacts for feedback generation.
Note, that both contactors must be rated for 400 V in this setup.

* **simultaneous** setup type: In this setup type both contactors are wired 'in parallel': while the
primary contactor switches neutral and one phase, the secondary contactor switches the phases 2 and 3.
As mentioned above, it is required that all phases appear simultaneously on the car side, not one after
another. To achieve this, from the software perspective, this mode ensures this by using the
Linux kernel's GPIO features. However, it also requires that the underlying GPIOs are located in the
same GPIO bank of the CPU. Fortunately, this is the case for the Charge Control C platform.

.. _switch-3ph1ph-simultaneous:
.. figure:: _static/images/switch-3ph1ph-simultaneous.drawio.svg
:width: 50%

Example wiring with two contactors in a 'simultaneous' setup, both with auxiliary contacts for
feedback generation. Note, that both contactors must be rated for 400 V in this setup.

.. note::

The IEC standard requires a physical/mechanical all-pole disconnect in emergency situations. So
using this wiring mode is only permitted when this requirement is satisfied, e.g. with RCD type B or EV.

* **mutual** setup type: In this setup type, two different contactors are used 'in parallel'. However,
it is important that only one contactor can be active at a time, i.e. they exclude each other *mutually*.
This is ensured by the software implementation, but should already be enforced in hardware,
e.g. by using the auxiliary contacts as shown in :numref:`switch-3ph1ph-mutual`.
This setup allow to use a single 400 V-rated contactor in combination with a (cheaper) 230 V-rated one.

.. _switch-3ph1ph-mutual:
.. figure:: _static/images/switch-3ph1ph-mutual.drawio.svg
:width: 60%
.. _switch-3ph1ph-mutual:
.. figure:: _static/images/switch-3ph1ph-mutual.drawio.svg
:width: 60%

Example wiring with two contactors in 'mutual' setup. The primary contactor must be
rated for 400 V, the secondary contactor can be rated for 230 V only.
Example wiring with two contactors in 'mutual' setup. The primary contactor must be
rated for 400 V, the secondary contactor can be rated for 230 V only.

As mentioned, the **CbTarragonDriver** module is the relevant hardware abstraction layer for EVerest
for the Charge Control C platform. The module must know which wiring type is used in the charger
and offers the configuration parameter **switch_3ph1ph_wiring** for this which can take the following strings:

* **none** (default): No phase-count switching is supported - only R1/S1 is used to switch on/off a single contactor.
* **serial**: Phase-count switching support is enabled using the serial wiring as described above: R1/S1 switches
the primary contactor, R2/S2 is attached to the secondary contactor.
the primary contactor (for N + L1-3), R2/S2 is attached to the secondary contactor (for L2 + L3).
* **simultaneous**: Phase-count switching support is enabled using the simultaneous wiring as described above: R1/S1 switches
the primary contactor (for N + L1), R2/S2 is attached to the secondary contactor (for L2 + L3).
* **mutual**: Phase-count switching support is enabled using the mutual wiring as described above. R1/S1 is wired to
the three-phase contactor, R2/S2 is wired to the single-phase contactor.
the three-phase contactor (for N + L1-3), R2/S2 is wired to the single-phase contactor (for N + Lx).

Snippet of an EVerest configuration file which fits the configuration for :numref:`switch-3ph1ph-mutual`:

Expand All @@ -122,6 +143,7 @@ Snippet of an EVerest configuration file which fits the configuration for :numre
...

.. note::

Older chargebyte configurations shipped with a `CbTarragonDriver` module parameter `relay_2_name` set to value `none`.
This was part of an older approach and should not be used that way. Remove it when it is still present,
so that the default value is applied automatically.