This project was developed for the course Computer Architecture and Organization I (INF01024 - UFRGS). The program, written in Assembly 8086, simulates an electric power quality analyzer by processing an input file with second-by-second voltage readings and generating a quality report.
See assignmentDefinition.md for more information.
- Reads command-line arguments (from PSP):
-i <file>: Input file (.in)-o <file>: Output file (.out)-v <value>: Nominal voltage value (127 or 220)
- Validates voltage measurements:
- Zero voltage (0)
- Good quality voltage: between 117–137 (for 127V) or 210–230 (for 220V)
- Generates a report including:
- Total number of seconds analyzed
- Time with good quality voltage
- Time with no voltage
- Outputs the report to both screen and output file (
.out)
- DOSBox
- MASM (Microsoft Macro Assembler)
-
Compile the program using MASM:
masm analyzer.asm; link analyzer.obj; -
Run it with desired arguments:
analyzer.exe -i a.in -o result.out -v 127
- Argument order does not affect execution.
- If the